A-
88/100

WHITE RIVER LODGE Inspection Report, Violations & Safety Grade (BEDFORD, Indiana)

3710 KENNY SIMPSON LN, BEDFORD, Indiana 47421

Phone: 8122757006

CMS Overall:4/5

Overview & Bed Count

Certified Beds
74
Avg Residents/Day
32.5
Ownership
Government - City/county
Provider Type
Medicare and Medicaid
County
Lawrence
Sprinkler Systems
Yes
Special Focus
None
Abuse Icon
No

CMS Star Ratings

Overall4/5
Health4/5
Staffing4/5
Quality2/5

Nurse Staffing Check

MetricThis FacilityIndiana AvgDifference
RN Hours per Resident per Day0.690.68+0.01
Total Nurse Hours per Resident per Day4.333.73+0.60
CMS Staffing Rating4/52.6/5-
Nursing Staff Turnover40.9%45.9%-

Health Citation History

5 health citations on record

DateCategoryDescriptionSeverity
2026-03-27Freedom from Abuse, Neglect, and Exploitation DeficienciesPrevent the use of unnecessary psychotropic medications or use medications that may restrain a resident's ability to function.D – Moderate Harm Potential
2026-03-27Quality of Life and Care DeficienciesProvide safe and appropriate respiratory care for a resident when needed.D – Moderate Harm Potential
2026-03-27Quality of Life and Care DeficienciesProvide or obtain dental services for each resident.D – Moderate Harm Potential
2025-06-02Pharmacy Service DeficienciesEnsure drugs and biologicals used in the facility are labeled in accordance with currently accepted professional principles; and all drugs and biologicals must be stored in locked compartments, separately locked, compartments for controlled drugs.D – Moderate Harm Potential
2025-06-02Infection Control DeficienciesProvide and implement an infection prevention and control program.D – Moderate Harm Potential

Fire Safety Citation History

12 fire safety citations on record

DateCategoryDescriptionSeverity
2026-03-27Emergency Preparedness DeficienciesConduct testing and exercise requirements.F – Moderate Harm Potential
2026-03-27Emergency Preparedness DeficienciesImplement emergency and standby power systems.F – Moderate Harm Potential
2026-03-27Smoke DeficienciesInspect, test, and maintain automatic sprinkler systems.F – Moderate Harm Potential
2026-03-27Services DeficienciesHave properly installed electrical wiring and gas equipment.F – Moderate Harm Potential
2026-03-27Miscellaneous DeficienciesHave simulated fire drills held at unexpected times.F – Moderate Harm Potential
2026-03-27Gas, Vacuum, and Electrical Systems DeficienciesEnsure receptacles at patient bed locations and where general anesthesia is administered, are tested after initial installation, replacement or servicing.F – Moderate Harm Potential
2026-03-27Gas, Vacuum, and Electrical Systems DeficienciesHave generator or other power source capable of supplying service within 10 seconds.F – Moderate Harm Potential
2026-03-27Gas, Vacuum, and Electrical Systems DeficienciesEnsure that testing and maintenance of electrical equipment is performed.F – Moderate Harm Potential
2026-03-27Egress DeficienciesAdd doors in an exit area that do not require the use of a key from the exit side unless in case of special locking arrangements.E – Moderate Harm Potential
2026-03-27Egress DeficienciesInstall emergency lighting that can last at least 1 1/2 hours.C – Minimal Harm Potential
2026-03-27Smoke DeficienciesFollow proper procedures when the fire alarm was out of service for more than 4 hours.C – Minimal Harm Potential
2026-03-27Smoke DeficienciesFollow proper procedures when the automatic sprinkler systems was out of service for more than 10 hours.C – Minimal Harm Potential

Total Penalties & Fines

$0
Total Fine Amount (CMS)
0
Number of Fines
0
Total Penalties

No penalty records found.

Need Help Finding Safe Care?

Our family advisors can help you find vetted, top-rated facilities in the BEDFORD area at no cost.